Issue 5 November 2000
363-206-208
Equipment and Rear Access Cabling for the DDM-2000 OC-12 Multiplexer
Lucent Technologies - Proprietary
See Notice on first page
Table 2-7
Power and Alarm Cable Assemblies
Description
ED-8C727-20 Group
Cable
Length (ft.)
Cable
Type
DDM-2000 Backplane
Connections
Office Alarms for
Bottom Shelf
174
150 816AS
‡
J63
191
50
192
250
175 (D.A.)*
As Reqd.
Office Alarms for Addi-
tional OC-12 Shelves
176
4’ 6"
816AS
‡
J64 to J63 (Lower Shelf)
193
20
J64 to J63 (Non-
Adjacent Shelves)
177 (D.A.)*
As Reqd.
Office Alarms for first
shelf in typical bay or
individual basis
ED-8C724-22 G46
250
816AS
‡
J63
Office Alarms MULT
from OC-3 Shelf
ED-8C724-22 G36
4’2”
P57 (OC-3) to
P63 (OC-12)
Office Alarms MULT
to Additional OC-3
Shelf
ED-8C724-20 G383
4’
816AS
‡
J64 (OC-12 Shelf) to
P56 (OC-3 Shelf)
OC-12 Shelf
Power Cable
150
2
12GA
J25
Power Cable for
Single OC-12 Shelf
ED-8C724-20 G371
15
12GA
P1, P2 of G150 Cable
or P3, P4 of G148
Cable.
Power Cable Riser for
Bay Arrangements
ED-8C724-20 G372
8
10GA
P1, P2 of G150 Cable
and P3, P4 of G148
Cable.
Fan Shelf
Alarm Cable
149
3’ 4"
812AS
‡
J68
181
150
147 (D.A.)*
As Reqd.
Fan Shelf Power
Cable
148
2
12GA
P1, P2 (Fan Shelf)
Table 2-7 Notes:
* Discontinued Availability means cable can no longer ordered.
‡ 812AS and 816AS cable is 26 gauge
Summary of Contents for DDM-2000 OC-12
Page 4: ......
Page 370: ...GL 22 Issue 5 June 2000 363 206 208 Glossary ...
Page 382: ...363 206 208 Index 1 ...