363-206-204
Equipment and Rear Access Cable Installation
Issue 9 October 1998 2-29
7. Stack the cables as shown in Figure 2-2 or Figure 2-3.
8. Dress and tie the cables in the bay as close to the DDM-2000 OC-3 back-
plane as possible without touching any backplane pins.
9. Cut the cable to the desired length. If the bottom shelf (shelf 1) position is
unequipped, leave enough cable so the cable can reach the bottom posi-
tion when the shelf is eventually added.
10. Wire-wrap the loose end of the DS1 timing cable to the DS1 reference
clock making connections per Table 2-14.