363-206-204
Release 6 Installation Tests
Issue 9 October 1998 5-5
Tools, Test Sets, and Accessories
The following items are required:
NOTE
:
When looping a 22G-U OLIU back on itself a 10 dB LBO is required.
Use of Terminal
Description
This procedure describes which terminals are approved for use with the
DDM-2000 OC-3, how to set up the terminal, and the DDM-2000 OC-3 command
structure which will be used.
Compatible Terminals
The DDM-2000 OC-3 craft interface terminal (CIT) port will support rates of 300,
1200, 2400, 4800, 9600, and 19,200 baud and should be compatible with most
ASCII terminals.
Quantity
Description
1
Wrist strap connected to the electrostatic discharge (ESD) jack on the
user panel for ESD protection
1
DSX-1 loopback cable
1
DSX-3 loopback cable or/and BNC to BNC connector
(for wiring to equipment not DSX-3)
1
ASCII Terminal or PC configured as a terminal
Optical fiber cable (recommended length is 2 feet) find your OLIU
type below
OLIU
Optical fiber cable (See Table 5-2)
1 per OLIU
22F
Single mode with ST
®
connector on each end
1 per OLIU
21G
Single mode with ST
®
connector on each end
1 per OLIU
21D
Multimode with ST
®
connector on each end
1 per OLIU
21D-U
22D-U
Multimode with ST
®
, FC/PC, or SC connector on each
end depending on Universal LBO used
(ST
®
0 dB LBO is standard See Table 5-1)
1 per OLIU
21G-U
22G-U
Single mode with ST
®
, FC/PC, or SC connector on each
end depending on Universal LBO used
(ST
®
0 dB LBO is standard See Table 5-1)
See Note Below
Summary of Contents for DDM-2000 OC-3
Page 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Page 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Page 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Page 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Page 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Page 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Page 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Page 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Page 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Page 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Page 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Page 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Page 492: ...IN 14 Issue 9 October 1998 ...