Issue 9 October 1998 10-1
Lucent Technologies
10
Operational Tests
Overview
This section provides instructions to test protection switching and the
nontransmission cabling. This section is not intended to replace acceptance test
procedures. If problems are encountered, refer to the "Troubleshooting" section of
this manual. For detailed troubleshooting, refer to the 363-206-202 (Releases 6
and 7), 363-206-280 (Releases 8, 9 and 11) or 363-206-285 (Release 13)
DDM-2000 OC-3 Multiplexer User/Service Manual
.
Test Equipment
The following equipment is required:
NOTE
:
All precautions should be observed when handling fiber.
!
WARNING:
Unterminated optical connectors may emit laser radiation. Do not view
beam with optical instruments.
Quantity
Description
1
Wrist strap connected to the electrostatic discharge (ESD)
jack on the user panel for ESD protection
1
ASCII Terminal or PC configured as a terminal
Summary of Contents for DDM-2000 OC-3
Page 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Page 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Page 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Page 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Page 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Page 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Page 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Page 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Page 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Page 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Page 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Page 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Page 492: ...IN 14 Issue 9 October 1998 ...