3-20 Issue 9 October 1998
363-206-204
Equipment and Front Access Cable Installation
For external interconnection requirements using the miscellaneous discrete
telemetry feature (Releases 6 and 7) at a remote terminal, refer to Figure 3-8 or
Figure 3-9 for a central office. For Releases 8, 9, 11 and 13 refer to Figure 3-10.
Remote applications not using environmental telemetry or fan alarm connections
require terminations.
Procedure
NOTE
:
There is no multing of miscellaneous (environmental) discrete telemetry
cables.
NOTE
:
This procedure should be performed for each shelf requiring miscellaneous
(environmental) discrete telemetry.
NOTE
:
Miscellaneous (environmental) discrete telemetry cable options are listed
in Table 3-4.
NOTE
:
Miscellaneous (environmental) discrete telemetry connections are listed in
Table 3-8 for remote terminal applications and Table 3-9 for central office
applications.
1. Obtain a miscellaneous (environmental) discrete telemetry cable Group
441 or 442 (refer to Table 3-4).
NOTE
:
The cable is connected to the front access cable on a shelf requiring mis-
cellaneous (environmental) discrete telemetry.
For RT applications not using environmental telemetry or fan alarm con-
nections (when Groups 441, 442 or 457 are not used) a G456 termination
must be connected to J262 on the cable.
2. Connect the cable to P261 if at a CO, or P262 if at an RT.
3. For remote terminal applications requiring more than 14 user definable
environmental inputs (Releases 8, 9, 11 and 13 only), connect a second
Group 441 or 442 cable to P261 of the Group 463 front access cable previ-
ously installed.
NOTE
:
The front access cable must be Group 463 and NOT Group 428 or 429 for
this application.
Summary of Contents for DDM-2000 OC-3
Page 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Page 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Page 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Page 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Page 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Page 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Page 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Page 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Page 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Page 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Page 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Page 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Page 492: ...IN 14 Issue 9 October 1998 ...