363-206-204
Powering, Verification, and Circuit Pack Installation
Issue 9 October 1998 4-17
Download Procedure
NOTE
:
Refer to the "Install New Generic Program" (DLP-532) of 363-206-202
(Releases 6 and 7), 363-206-280 (Releases 8, 9 and 11) and 363-206-285
(Release 13),
DDM-2000 OC-3 Multiplexer, User/Service Manual
while
performing the following procedure. If unfamiliar with the operation of the
PC, refer to the "Introduction to the PC" (DLP-533) of any of these
DDM-2000 OC-3 Multiplexer, User/Service Manuals.
1. With the PC not connected to the DDM-2000 OC-3 shelf, insert the first
diskette into the PC.
2. Use the appropriate MS-DOS command (for example, a: or b:) to go to the
drive where the diskette is inserted.
3. Enter the term command. Observe the message that is printed. Verify that
the PC is set for the same baud rate as the BBG5 circuit pack. The mes-
sage gives the user the choice to continue or not continue with the down-
load procedure. If the user chooses to continue, observe the following
response:
CTRM ready. (Type Alt-h for help.)
Communications established
4. Connect the PC to the CIT connector on the front of the shelf user panel.
5. Press the RETURN (or ENTER) key on the PC (press twice for Releases 8,
9, 11 and 13).
Response:
/*Enter a shelf number from 1 to 8*/
shelf [default]=
6. Again press the RETURN (or ENTER) key.
Response:
In Progress .....
NOTE
:
A series of dots following the ‘In Progress’ will continue while the software
is downloaded. A prompt will be displayed when the next diskette is
required.
7. Remove the existing diskette and insert the next diskette.
After the completion of the software download, a message ins-prog: TID
COMPLD will appear.
8. For Releases 7.2, 8, 9 and 11, an AGNE alarm will exist upon completion of
the download. To extinguish this alarm, set the AGNE to yes by using the
set-ne
command.
Summary of Contents for DDM-2000 OC-3
Page 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Page 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Page 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Page 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Page 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Page 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Page 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Page 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Page 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Page 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Page 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Page 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Page 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Page 492: ...IN 14 Issue 9 October 1998 ...