Lucent Technologies Supplemental Battery Stand J85504D-1 List 16
Issue 2 September 2000
Installation Guidelines and Preparations 5 - 5
Table 5-B: Anchor Bolt Specifications
Specification
HDI - 1/2
M12/0
M16/25
mm
in
mm
in
mm
in
Drill Bit Diameter = Anchor OD
16
5/8
18
11/16
24
1
Hole Depth
51
2
100
4
125
5
Min. Depth of Embedment
51
2
80
3-5/32
105
4-1/8
Max. Thickness Fastened
--
25
1
25
1
Anchor Length
51
2
120
4-11/16
148
5-15/16
Usable Thread Length
17
11/16
Head Washer
--
--
11
7/16
14
9/16
Wrench Size
HSL/HSLG
HSLB
--
--
19
24
3/4
15/16
24
30
15/16
1-3/16
Max. Gap Between Concrete and
Fastened Material
--
--
8
5/16
9
3/8
Min. Base Material Thickness (mm)
--
--
160
6-1/4
180
7-3/32
Specification
HDI - 1/2
M12/0
M16/25
N-m
ft-lbs
N-m
ft-lbs
N-m
ft-lbs
Max. Tightening Torque
29.8
22
**82
**60
204
150
Specification
Tension
lbs
Shear
kN
Tension
lbs
Shear
kN
Tension
lbs
Shear
kN
Ultimate Load in 4000 psi
7140
31.8
8500
37.8
11240
50.0
18900
84.1
20205
90.1
33640
149.6
Hand Setting Tool
Automatic Setting Tool
HST 1/2 000329805
TE-C-SD-12
00032980
Drill Bit (Hilti)
TE-C+18/20
TE-Y-18/34
TE-C+24/25
TE-P24/32
Notes:
* Use Hilti Setting Tool
** Initial installation of HSLB anchor requires no torque wrench. The torque cap shears off
at a predetermined torque value.