Important! The entries (*1) in the fiber guides are counted from the
front (first entry) to the back of the bracket (fourth entry). The cables
are tied together with velcro at the entries (*2) of the rack frame and
subrack
Upper subrack
The upper subrack cables are using the third entry of the fiber guide
(a) to route down first and then upwards to:
•
The upper row via the first entry (b)
•
The bottom row directly
Bottom subrack
The bottom subrack cables are using the fourth entry of the fiber
guide (c) to route down first and then upwards to:
•
The upper row via the first entry (d)
•
The bottom row directly
Fiber cabling
Fiber management in rack
System cabling and final assembly
....................................................................................................................................................................................................................................
4 - 6 4