Circuit packs
....................................................................................................................................................................................................................................
Overview
This section gives an overview about the available circuit packs. The
comcodes for the optical circuit packs are given in Appendix C,
“Ordering codes and specifications”.
Available circuit packs
The following circuit packs are used in the LambdaUnite
™
MSS shelf:
Short
Names
Function
Ports
per
pack
Max.
packs
per
shelf
Max.
ports
per
shelf
OP40G
Optical Interface Unit OC-768 /
STM-256
1
8
8
OP10G
Optical Interface Unit OC-192 /
STM-64 / 10-Gbit/s Ethernet
WANPHY
1
32
32
OP2G5
Optical Interface Unit OC-48 /
STM-16
4
32
128
OP2G5
Optical Interface Unit OC-48 /
STM-16 pWDM
2
32
64
OP622M
Optical Interface Unit OC-12 /
STM-4
16
32
512
OP155M
Optical Interface Unit OC-3 /
STM-1
16
32
512
GE1/SX4
Optical Interface Unit 1-Gigabit
Ethernet
4
32
128
XC320
Switching Unit (incl. timing
generator function) (upgradable)
n/a
2
n/a
CTL
System controller and DCC
controller unit (upgradable,
protection controller in future
release)
n/a
1
n/a
For the optical interface units, there is a second level of identification
(qualifier) which carries information about reach, lambda and other
variants, e.g. OP10G/1.5LR1, or OP40G/1.3IOR1 (see Appendix C,
“Ordering codes and specifications”).