Legend
Circuit pack
Valid slots
2
XC320 (protection) or
blank front plate (6N)
#10
3
User panel —
CC848730636
#40
4
Blank front plate (3N)
#31
5
Any optical circuit pack
(OP155M, OP622M,
OP2G5, OP10G, OP40G or
GE1) or
blank front plate (3N)
#01 ... #08, #12 ... #19,
#21 ... #28, #32 ... #39
Each optical board covers
the following positions:
•
OP155M - 1 slot
•
OP622M - 1 slot
•
OP2G5 - 1 slot
•
OP10G - 1 slot
•
OP40G - 4 slots
•
GE1 - 1 slot.
6
CTL (working)
#11
Gigabit Ethernet and 10-Gbit/s port units
It is recommended, to avoid thermic stress, not to place a 10-Gbit/s
port unit directly above a Gigabit Ethernet port unit.
Optical port unit protection
In the case of optical port protection (1+1 Linear APS / 1+1 MSP) it
is recommended to place the working port unit and the protection port
unit side by side for ease of maintenance.
Circuit pack installation
Slot positions of the circuit packs
Powering, circuit pack installation, and NE software
download
....................................................................................................................................................................................................................................
5 - 1 4
Lucent Technologies
365-374-074