Result:
The
Screen 3 of 3
opens.
The current data of the cross connection are displayed.
............................................................................................................................................................
13
Select
NORM
as
Output Mode
in the group boxes
Source to
Destination
and
Destination to Source
.
............................................................................................................................................................
14
Type a 9-digit number for the cross connection in the field
XC
Number
or use the automatically generated one.
............................................................................................................................................................
15
Click on the
Finish
button to apply your settings.
............................................................................................................................................................
16
Repeat
to
for all the other required cross-connections
according to the test setup.
Important! Use in
always the same cross-connection rate!
............................................................................................................................................................
17
Start a signal transmission via the SDH/SONET analyser for 3
minutes.
Result:
No bit errors are present during
Port transmission test (daisy chain test)
Stand alone test procedures
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
Lucent Technologies
7 - 1 5
E