Line timing provisioning
....................................................................................................................................................................................................................................
Overview
This section provides a procedure which must be carried out before
performing the line timing test (see section
).
Be If necessary existing timing references must be deleted before
Before you begin
Prior performing this task,
•
you must have at least a privilege code of P3
•
the DCC channels must be configured correctly (see section
•
the correct synchronisation system mode (SDH) must be selected
(see Chapter 6, section
•
existing timing references must be deleted.
Procedure
Proceed as follows to configure the line timing reference:
............................................................................................................................................................
1
Login to the NE-A as described in Chapter 6, section
............................................................................................................................................................
2
Select
Configuration
→
Timing/Sync
in the
System View
of the
WaveStar
®
CIT.
Result:
The window
Synchronisation Characteristics
appears.
............................................................................................................................................................
3
Select the tab
Line Reference 1
and set the following parameters:
•
Select
PRC
in the
Provisioned Quality Level
drop-down list
box.
•
Select the priority
1
in the drop-down list box
System Timing
Reference Priority
.
•
Select the port AID in the drop-down-list box
Assigned Port
AID
. Click on
Browse...
in order to open the window
Select
Line Timing Port AID
.
SDH test procedures
Span / Ring testing
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
Lucent Technologies
8 - 1 5