NOTE: Only ports to which fiber cables are connected can be
configured for line timing!
•
Select
Monitored
in the drop-down list box
Timing Port Mode
Monitoring
.
............................................................................................................................................................
4
Check that only the line timing reference is enabled. If not, disable all
other timing sources.
............................................................................................................................................................
5
Select the tab
System Timing
, then again the tab
System Timing
and
set the following parameters:
•
Set the
Wait To Restore
(WTR) time to
1 minute
.
•
Set the
Clock Mode
to
Locked
.
............................................................................................................................................................
6
Click on the
Apply
button and then
Yes
in the confirmation window.
............................................................................................................................................................
7
Repeat
to
for all other NEs within the ring/network.