Provision DCC
....................................................................................................................................................................................................................................
Purpose
Use this procedure to create new DCC (Data Communication
Channel) terminations. They are necessary for exchanging network
management information between NEs and performing the tests
described in this chapter.
Before you begin
Important! Only ports to which fiber cables are connected should be
configured for DCC terminations!
Prior performing this task,
•
you must have at least a privilege code of S4
•
a XC320 circuit pack must be plugged.
Max. number of active DCC
links
The maximum number of simultaneously supported DCC channels per
DCC controller is 64. That means, each DCC controller can support
up to 64 active DCC links.
Procedure
Proceed as follows to create a new DCC termination:
............................................................................................................................................................
1
Login to the NE as described in Chapter 6, section
............................................................................................................................................................
2
Invoke the
Configure DCC Terminations
window from the
System
View
main menu via
Configuration
→
DCC Terminations...
............................................................................................................................................................
3
Select the circuit pack for which you want to configure the DCC
terminations and click
Select
.
............................................................................................................................................................
4
Select
New Termination
in the parameter part (tab
Section DCC
).
............................................................................................................................................................
5
Click on
Select port for new DCC termination...
and select the
optical interface port for which you want to configure the DCC
terminations.
SONET test procedures
Span / Ring testing
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
Lucent Technologies
8 - 2 9