Line timing provisioning
....................................................................................................................................................................................................................................
Overview
This section provides a procedure which must be carried out before
performing the line timing test (see section
).
Before you begin
Prior performing this task,
•
you must have at least a privilege code of P3
•
the DCC channels must be configured correctly (see section
•
the correct synchronisation system mode (SONET) must be
selected (see Chapter 6, section
).
•
existing timing references must be deleted.
Procedure
Proceed as follows to configure the line timing reference:
............................................................................................................................................................
1
Login to the NE-A as described in Chapter 6, section
............................................................................................................................................................
2
Select
Configuration
→
Timing/Sync
in the
System View
of the
WaveStar
®
CIT.
Result:
The window
Synchronisation Characteristics
appears.
............................................................................................................................................................
3
Select the tab
Line Reference 1
and set the following parameters:
•
Select
PRS
in the
Provisioned Quality Level
drop-down list
box.
•
Select the priority
1
in the drop-down list box
System Timing
Reference Priority
.
•
Select the port AID in the drop-down-list box
Assigned Port
AID
. Click on
Browse...
in order to open the window
Select
Line Timing Port AID
.
SONET test procedures
Span / Ring testing
....................................................................................................................................................................................................................................
8 - 3 4
Lucent Technologies
365-374-074
Issue a, April 2002