Remote login failure
....................................................................................................................................................................................................................................
Overview
The procedure described below should be performed if no remote
login is possible (see Chapter 8, section
Procedure
Follow the steps below in the case of a remote login failure:
............................................................................................................................................................
1
Check that the DCC channels are configured correctly (see Chapter 8,
section
IF ...
THEN ...
a remote login is not
possible,
proceed to step 2.
a remote login is possible,
END OF STEPS
..........................................................................................................................................................
2
Reset the CTL circuit pack of the near-end NE. To do this, open the
latches simultaneously and wait until the red LED is illuminating
continously. Then pull and move back the controller.
IF ...
THEN ...
a remote login is not
possible,
proceed to step 3.
a remote login is possible,
END OF STEPS
..........................................................................................................................................................
3
Reset the CTL circuit pack of the far-end NE.
IF ...
THEN ...
a remote login is not
possible,
proceed to step 4.
a remote login is possible,
END OF STEPS
..........................................................................................................................................................
4
Perform a reload of the NE software to the CompactFlash card of the
near-end NE (see
Appendix B, “NE software installation”
Installation trouble shooting
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
Lucent Technologies
A - 9