Features
Page 174
CTI (Computer Telephony Integration) Link
Software using the CTI link can perform the following actions on a user’s
computer:
■
Screen pop
■
Power dial
■
Basic call control
CTI link applications can control functions at extensions with MLX or analog
multiline telephones.
Following are brief descriptions of the platform requirements for a CTI link as well
as the features listed above. For more detailed information about these features,
see the
PassageWay Telephony Services Network Manager’s Guide
.
Platform Requirements
9
A CTI link requires the following equipment and software:
■
MERLIN LEGEND Communications System Release 5.0 or later, in
Hybrid/PBX mode
■
A standalone LAN telephony server with an Intel® i386, i486, or Pentium®
class central processing unit and at least 16 megabytes of RAM (more
memory may be needed; see
PassageWay Telephony Services Network
Manager’s Guide
for details).
■
Novell NetWare version 3.12, 4.1, or 4.11
NOTE:
For a NetWare version 3.12 installation, additional files must be
obtained from Novell’s web site. For details, see
PassageWay
Telephony Services Network Manager’s Guide
.
■
5 megabytes of available disk space in the system volume
■
PassageWay Telephony Services for NetWare software, Release 2.21 or
later
■
Eicon/G. Diehl SCOM circuit board with an available 8- or 16-bit ISA slot, to
link the communications system and the telephony server
■
An MLX line/trunk or extension module, with a free extension jack (not the
first or fifth or any port programmed as an operator or programming
console), installed in the communications system control unit. The firmware
vintage should be 28 or later,
not including
vintage 29.
NOTE:
If the MLX module for the CTI link is the only MLX module in the
system, SPM software, version 5.01 or later, is also required in order
to program the CTI link.