Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Rack-Mount)
Office Alarm Cable Installation
...........................................................................................................................................................................................................................................................
2 - 2 7
365-372-334 R2.0
Issue 4, November 2004
Procedure
Step 1
Obtain the office alarm cable per Table 2-9, Office Alarm Cable
Assemblies (page 2-26). Connect the office alarm cables to the
ALARM terminal block in the lower left hand side of the access panel
on the rear of the Rack-Mount Metropolis
®
DMXplore shelf. See
Figure 2-12, Office Alarm Cable Connections (page 2-28) and
Figure 2-11, Alarm Designations (as shown on inside cover) (page
2-28) for details.
Important!
The recommended wire strip length for cables being
connected to the alarm block is 11mm. Use the guide located on the
inside of the cover on the lower right hand for accurate lengths.
Table 2-10
Office Alarm Connections
Pin#
Color
Name
Designation
1
2
BL
BL/W
CR/MJ Visual
CR/MJ Visual
RYCRMJV1
3
4
O
O/W
CR/MJ Audible
CR/MJ Audible
RYCRMJA1
5
6
G
G/W
MN/ABN Visual
MN/ABN Visual
RYMNABNV1
7
8
BR
BR/W
MN/ABN Audible
MN/ABN Audible
RYMNABNA1
Notes:
1. The SYSCTL circuit pack reports office alarms.
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...