Operational Tests
Office Alarm Test
...........................................................................................................................................................................................................................................................
7 - 5
365-372-334 R2.0
Issue 4, November 2004
Procedure
Step 1
Use the scroll bar in the
Command Builder
window to scroll down to
the
ent-rr
command.
Important!
For DS1 ports, rr is t1 and for DS3 ports, rr is t3.
...........................................................................................................................................................................
Step 2
Click on the
ent-rr
command.
...........................................................................................................................................................................
Step 3
Under the
Parameters
section,
<rrAID>,
click on
{x}-{1}-{1}
for DS1
parameters and
{x}-{1}
for DS3 parameters.
Important!
For DS1 ports, x is a and for DS3 ports, x is b.
Table 7-1
Office Alarm Connections
Pin#
Color
Name
Designation
1
2
BL
BL-W
CR/MJ Visual
CR/MJ Visual
RYCRMJV1
3
4
O
O-W
CR/MJ Audible
CR/MJ Audible
RYCRMJA1
5
6
G
G-W
MN/ABN Visual
MN/ABN Visual
RYMNABNV1
7
8
BR
BR-W
MN/ABN Audible
MN/ABN Audible
RYMNABNA1