Operational Tests
Miscellaneous (Environmental) Discrete
Telemetry Test
...........................................................................................................................................................................................................................................................
7 - 1 5
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................
MDI Test Procedure
Step 1
Determine which environmental inputs are to be monitored via the
Metropolis
®
DMXplore shelf.
...........................................................................................................................................................................
Step 2
Verify that the miscellaneous discrete cables are connected to the
MDI
connector block on the Access Panel. See Figure 1-16, Miscellaneous
Discrete Cable Connection (page 1-39)
...........................................................................................................................................................................
Step 3
Refer to Table 7-2, Miscellaneous (Environmental) Discrete Inputs
Telemetry Connections (page 7-15) to determine the wire color of the
cable lead associated with the environmental input to be tested.
...........................................................................................................................................................................
Step 4
At the far end of the cable, short the associated environmental input
lead to the red-slate (R-S) Input Common lead.
...........................................................................................................................................................................
Step 5
Verify that the minor (
MN/ABN
) alarm lights on the SYSCTL.
Table 7-2
Miscellaneous (Environmental) Discrete Inputs Telemetry
Connections
Pin#
Color
Designation
Name
1
2
3
4
BL
BL-W
O
O-W
TLMI1
TLMOC
TLMI2
TLMOC
Env. Input - #1
Output Common
Env. Input - #2
Output Common
5
6
7
8
G
G-W
BR
BR-W
TLMI3
TLMOC
TLMI4
TLMOC
Env. Input - #3
Output Common
Env. Input - #4
Output Common
Note: Output commons are tied together internally. It is necessary only
to connect one output common to a ground source.
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...