Ring Setup and Testing: Integration Procedures
Fiber Installation
...........................................................................................................................................................................................................................................................
8 - 5
365-372-334 R2.0
Issue 4, November 2004
Procedure
The following procedures are performed at each end of the optical span
being tested.
Step 1
Verify that the office alarm cabling to the
ALARM
terminal block on
the access panel of the Metropolis
®
DMXplore shelf is disconnected. If
the shelf to be tested is part of a multiple shelf bay arrangement, the
office alarm cable connects to shelf 1.
...........................................................................................................................................................................
Step 2
At each DMXplore shelf, enter the shelf TID per the customer order or
use LT-DMXPLORE-1 and LT-DMXPLORE-2 as defaults using the
ENT-SYS command.
...........................................................................................................................................................................
Step 3
Use the scroll bar in the
Command Builder
window to scroll down to
the
dlt-crs-zzz
command. Select
x-1-all
under
<zzzAIDCRSSRC>
and
m-1-{1}-all
under
<zzzAIDCRSDST>
.
Result:
A command similar to the following example will be
displayed in the command window to the left of the
Send
button.
Example:
dlt-crs-vt1:lt-dmxplore:a-1-all,m-1-1-all:1::2WAYPR;
Important!
For DS1, zzz is VT1, x is a.
...........................................................................................................................................................................
Step 4
Click
Send
to issue the command.
Result:
All VT1.5 default cross connections on the shelf will be
deleted.
...........................................................................................................................................................................
Step 5
If you have a VLNC5 or VLNC25 circuit packs in Main, you must
delete the default DS3 cross-connects. Use the scroll bar in the
Command Builder
window to scroll down to the
dlt-crs-zzz
command. Select
x-all
under
<zzzAIDCRSSRC>
and
m-1-all
under
<zzzAIDCRSDST>
.
Result:
A command similar to the following example will be
displayed in the command window to the left of the
Send
button.
Example:
dlt-crs-sts1:lt-dmxplore:b-all,m-1-all:1::2WAYPR;
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...