Ring Setup and Testing: Integration Procedures
Automatic Protection Switching Test
...........................................................................................................................................................................................................................................................
8 - 1 3
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
Automatic Protection Switching Test
Description
This section provides the procedures for verifying the Metropolis
®
DMXplore shelf automatic and manual protection switching.
This test may be performed on the VLNC5, VLNC6, VLNC25 and
VLNC26 circuit packs. Use the OC 3 commands for the VLNC5 and
VLNC6 circuit packs and the OC12 commands for the VLNC25 and
VLNC26 circuit packs.
Note the following:
•
These tests do NOT simulate circuit pack failures.
•
A properly grounded wrist strap must always be worn while
handling circuit packs.
•
Prior to performing each test, the shelf under test must be
clear of all alarms (that is, only green LEDs are lighted).
...........................................................................................................................................................................
MAIN OLIU Switch Test
Step 1
There must be cross-connects present to complete this test. Enter
VT1.5 cross connects with the
ent-crs-vt1:lt-dmxplore:a-1-1-all,m-1-
1-all:1::2WAYPR;
command. Enter STS1 cross-connects with the
ent-crs-
sts1:lt-dmxplore:b-all,m-2-all:1::2WAYPR;
...........................................................................................................................................................................
Step 2
Click
Send
to issue the command.
Result:
All VT1.5 and STS1 cross connections to the shelf will be
entered followed with a COMPLD message.
...........................................................................................................................................................................
Step 3
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-state-path
command.
...........................................................................................................................................................................
Step 4
Click on the
rtrv-state-path
command. Select
m{1}-1-{all}
under
<STATEAIDRTRV>
.
...........................................................................................................................................................................
Step 5
Click
Send
to issue the command.
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...