Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Rack-Mount)
Planning
2 - 6
365-372-334 R2.0
Issue 4, November 2004
Metropolis
®
DMXplore (not included with equipment).
3. One "Single DS1 Cable Assembly" is required for each DS1 supported by
the main pack (maximum of 16). Each DS1 Cable Assembly supports 1
pair of 24-gauge RJ45/blunt-cut or RJ45-RJ45 cables. One cable is for
input and output signals.
4. One "Single DS3 Cable Assembly" is required for each DS3 supported by
the main pack. One code provides 1 DS3 input and 1 DS3 output, 735A
coaxial Straight BNC plug to Straight BNC plug.
5. When cabling the Metropolis
®
DMXplore for office alarm applications,
one Office Alarm Cable Assembly is required for each Metropolis
®
DMXplore shelf.
6. When accessing the shelf through the LAN (OSI/TCP-IP) connection,
either a LAN 10BASE-T cross-over cable or a LAN 10BASE-T straight-
through cable is required to access the shelf. The cross-over cable should
be used when connecting directly between the shelf from a PC NIC card.
The straight-through cable should be used when connecting the shelf to a
hub.
...........................................................................................................................................................................