Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXtend Shelf Horizontal Bay Mount
Circuit Pack Compatibility
2 - 1 0
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
Figure 2-2
Metropolis
®
DMXtend Shelf
LNW43
**
LNW42
††
LNW95
‡‡
LNW96
***
LNW98
†††
LNW98
* 177D Apparatus Blanks are required in all unequipped Function
Unit slots to provide proper air flow for cooling.
† LNW71 and LNW66, 100 BASE-TX ethernet interface,
may only occupy slot 1 of a function group.
‡ LNW67 and LNW68, 1000 BASE-SX/LX optical ether-
net interface, may only occupy slot 1 of a function group.
** LNW43 Apparatus Blanks are required in all unequipped A/B
Slots to provide proper air flow for cooling.
†† LNW42 Apparatus Blanks are required in all unequipped Main
Slots to provide proper air flow for cooling.
‡‡ LNW95 System Detectable Blank Card for slot M2. Apparatus
Blanks are required in all unequipped Main Slots to provide prop-
er air flow for cooling.
*** LNW96 System Detectable Blank Card for slots A1/B1 and
A2/B2. Apparatus Blanks are required in all unequipped A/B
Slots to provide proper air flow for cooling.
††† LNW98 System Detectable Blank Card for slots D and G.
Apparatus Blanks are required in all unequipped Function Unit
slots to provide proper air flow for cooling.
**** LNW37 is a SFP (Small Form-Factor Pluggable) pluggable
optic pack
Table 2-4
Release R2.0 Circuit Pack Slot Compatibility
Slot Name
CTL
G1, G2
*
A1/B1,
A2/B2
M1, M2
D1, D2
*