Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXtend Shelf Horizontal Bay Mount
Initial Circuit Pack Installation
...........................................................................................................................................................................................................................................................
2 - 1 7
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 8
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps
LNW36 (OC-3 OLIU) (R1.1)
Low Speed Installation
(Optional)
Follow this procedure only if installing LNW36 (OC-3 OLIU)
(Supported starting in release R1.1) circuit packs into the Metropolis
®
DMXtend shelf.
Step 1
Refer to the engineering job specification. Identify the proper function
group(s) and/or growth slot(s) where LNW36 (OC-3 OLIU) circuit
pack will be installed.
............................................................................................................................................................................
Step 2
Remove the LNW36 (OC-3 OLIU) from the packing material.
............................................................................................................................................................................
Step 3
Place the circuit pack into the shelf (slot D1 or G1 as required). Do
NOT engage the circuit pack in the backplane connector.
............................................................................................................................................................................
Step 4
If a companion circuit pack is required, continue with the Step 5. If not,
install a 177D or LNW98 Apparatus Blank into the protection circuit
pack slot (D2 or G2 as required) then proceed to Step 7.
Important!
177D or LNW98 Apparatus Blanks are required in all
unused slots D and G to provide proper air flow for cooling.
............................................................................................................................................................................
Step 5
Remove the second LNW36 (OC-3 OLIU) from the packing material.
............................................................................................................................................................................
Step 6
Place the circuit pack into the shelf (slot D2 or G2). Do NOT engage
the circuit pack in the backplane connector.
............................................................................................................................................................................
Step 7
Repeat Step 1 through Step 6 for each additional function group and/or
growth slot to be equipped with LNW36 (OC-3 OLIU) circuit packs.