Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXtend Shelf Horizontal Bay Mount
Initial Circuit Pack Installation
2 - 1 8
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 8
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps
LNW37 (OC-3 SFP OLIU)
(R2.0) Low Speed
Installation (Optional)
Follow this procedure only if installing the LNW37 (OC-3 SFP OLIU)
(supported starting in release R2.0) circuit packs into the Metropolis
®
DMXtend shelf.
Important!
The LNW37 OC-3 SFP circuit pack comes in two
separate boxes. One box containing the circuit pack, the other
containing the ordered quantity of SFPs. This procedure will consist
of two parts installing the circuit card and the other installing the
SFP.
Step 1
Refer to the engineering job specification. Identify the proper function
group(s) and/or growth slot(s) where LNW37 (OC-3 SFP OLIU)
circuit pack will be installed.
............................................................................................................................................................................
Step 2
Remove the LNW37 (OC-3 SFP OLIU) from the packing material.
............................................................................................................................................................................
Step 3
Place the circuit pack into the shelf (slot D1 or G1 as required). Do
NOT engage the circuit pack in the backplane connector.
............................................................................................................................................................................
Step 4
If a companion circuit pack is required, continue with the Step 5. If not,
install a 177D or LNW98 Apparatus Blank into the protection circuit
pack slot (D2 or G2 as required), then proceed to Step 7.
Important!
177D or LNW98 Apparatus Blanks are required in all
unused slots D and G to provide proper air flow for cooling.
............................................................................................................................................................................
Step 5
Remove the second LNW37 (OC-3 SFP OLIU) from the packing
material.
............................................................................................................................................................................
Step 6
Place the circuit pack into the shelf (slot D2 or G2 as required).