Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXtend Shelf Horizontal Bay Mount
Initial Circuit Pack Installation
...........................................................................................................................................................................................................................................................
2 - 2 5
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 3
Place the 177D or LNW98 Apparatus Blank into an unequipped slots D
and G on the shelf. Do NOT engage the blank pack in the backplane
connector.
............................................................................................................................................................................
Step 4
Continue with the next unequipped D and G slot until all the unused
slots are equipped with an 177D or LNW98 Apparatus Blank.
............................................................................................................................................................................
Step 5
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps
LNW43, LNW96 (R1.1)
Apparatus Blank
Installation (Optional)
Follow this procedure to installs LNW43 or LNW96 (Supported
starting in release R1.1) Apparatus Blank(s) into the Metropolis
®
DMXtend shelf.
Important!
A LNW43 or LNW96 (R1.1) Apparatus Blank is
required in any unequipped A1/B1 or A2/B2 slots to provide proper
air flow for cooling.
Step 1
Identify any unequipped A1/B1 or A2/B2 slots.
............................................................................................................................................................................
Step 2
Remove the LNW43 or LNW96 (R1.1) Apparatus Blank from the
packing material.
............................................................................................................................................................................
Step 3
Place the LNW43 or LNW96 (R1.1) Apparatus Blank into the
unequipped A/B slot on the shelf. Do NOT engage the blank pack in
the backplane connector.
............................................................................................................................................................................
Step 4
Continue with the next unequipped slot until all the unused A1/B1 or
A2/B2 slots are equipped with an LNW43 or LNW96 (R1.1) Apparatus
Blank.