Software Download and Circuit Pack Installation
Metropolis
®
DMXtend Shelf Initialization
3 - 2 0
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 6
In the command window to the left of the
Send
button select and
highlight the following portion of the command
:
[!!! SERVICE AFFECTING !!!]
Delete that portion of the command.
Result:
A command similar to the following example should be
displayed in the command window to the left of the
Send
button.
Example:
init-sys:
LT-DMXTEND
:all:1::9;
............................................................................................................................................................................
Step 7
Click
Send
to issue the command.
Result:
The shelf will reset and end the cit session.
............................................................................................................................................................................
Step 8
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps