Installation Tests
LBO Software Settings
...........................................................................................................................................................................................................................................................
4 - 3
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
LBO Software Settings
Description
This section provides instructions for setting the software Line Build
Out (LBO) for the DS1, and DS3/EC1 cabling and requires that the
SYSCTL, DS1, and/or DS3/EC1 circuit packs be installed and that
software has been downloaded.
............................................................................................................................................................................
Setting DS1, and DS3/EC1
LBOs
Follow this procedure to set the LBOs for the DS1, DS1/DS3/16/3 and
DS3/EC1 circuit packs.
Step 1
Log on to the Metropolis
®
DMXtend shelf using the CIT software as
described in the Use of WaveStar™ CIT Software (page 3-8).
............................................................................................................................................................................
Step 2
Refer to the following table of cable lengths and LBO values.
Determine the LBO value corresponding to the DS1 cables installed.
............................................................................................................................................................................
Step 3
Use the scroll bar in the
Command Builder
window to scroll down to
the
ent-t1(sb)
command.
............................................................................................................................................................................
Step 4
Click on the
ent-t1(sb)
command.
............................................................................................................................................................................
Step 5
Under the
Parameters
section,
<T1AID>,
click on
{a}-all.
Double click on {a} and choose the Function Group where the LNW6/
LNW7 or LNW39 is located.
............................................................................................................................................................................
Step 6
Under the
Parameters
section,
<T1SB>,
click on
LBO={20}.
LBO Value
Distance (feet)
Cable Type 1161A
20
0 - 133 (default)
40
133 - 267
60
267 - 420
80
420 - 533
100
533 - 655