Installation Tests
LBO Software Settings
4 - 4
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
Double click on {20} and choose the LBO value determined in Step 2.
Result:
A command similar to the following example should be
displayed in the command window to the left of the
Send
button.
Example:
ent-t1:lt-dmxtend:a-all:ctag:::LBO=20;
............................................................................................................................................................................
Step 7
Click
Send
to issue the command.
Result:
The
Response Window
should display the command
followed by a
COMPLD
indication.
DS3/EC1
The DS3/EC1 cabling will be tested with all ports provisioned for DS3.
Set DS3 LBO values as follows.
............................................................................................................................................................................
Step 8
Refer to the following table of cable lengths and LBO values.
Determine the LBO value corresponding to the DS3 cables installed:
............................................................................................................................................................................
Step 9
Use the scroll bar in the
Command Builder
window to scroll down to
the
ent-t3(sb)
command.
............................................................................................................................................................................
Step 10
Click on the
ent-t3(sb)
command.
............................................................................................................................................................................
Step 11
Under the
Parameters
section,
<T3AID>,
click on
{b}-{1}.
Double click on {b} and choose the Function Group where the LNW16
or LNW39 is located.
Double click on {1} and choose all.
............................................................................................................................................................................
Step 12
Under the
Parameters
section,
<T3SB>,
click on
LBO={IN}.
LBO Value
Distance (feet)
Cable Type 735A and 734D
IN
0 - 65 (default)
OUT
> 65