Installation Tests
Local Equipment and Cross-connect Tests
4 - 1 0
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
DS1 Testing Procedure
Perform the following steps for all Metropolis
®
DMXtend shelf
Function Unit slots that are cabled to a DSX-1.
Function Unit slot A/B cabled to the DSX-1 must contain a DS1/DS3/
16/3 (LNW37) circuit pack in order to perform these tests on the DS1
portion of the cabling. Function Unit slot D or G cabled to the DSX-1
must contain either a 28DS1 (LNW6 or LNW7) or 56DS1PM (LNW8)
(Supported in release R1.1) circuit pack in order to perform these tests.
If the Metropolis
®
DMXtend shelf is not fully populated, it may be
necessary to move the circuit pack(s) from slot to slot in order to test all
DS-1 cabling.
Important!
The LNW39 (DS1/DS3/16/3) circuit pack only
supports the first 16 DS1’s of the A function group. The cabling for
DS1s 17 thru 28 will not be tested.
This procedure requires the use of a DS1 test set.
Step 1
Set the DS-1 test set to transmit and receive a Quasi-Random Sequence
Signal (QRSS) with B8ZS formatting.
............................................................................................................................................................................
Step 2
Connect a cable from the DS-1 test set transmit connection to the
IN
jack of the DSX-1 associated with the DS-1 tributary to be tested (start
with the first).
............................................................................................................................................................................
Step 3
Connect a cable from the DS-1 test set receive connection to the
OUT
jack of the DSX-1 associated with the DS-1 tributary to be tested (start
with the first).
Result:
The DS-1 test set should indicate a blue (AIS) signal is
being received.
............................................................................................................................................................................
Step 4
Use the scroll bar in the
Command Builder
window to scroll down to
the
ent-crs-vt1
command.
............................................................................................................................................................................
Step 5
Click on the
ent-crs-vt1
command.
............................................................................................................................................................................
Step 6
Under the
Parameters
section,
<VT1AIDCRSSRC>
, click on
m-1-{1}-
{1}-{1}
.