Installation Tests
Local Equipment and Cross-connect Tests
4 - 1 4
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
DS3/EC1 Testing Procedure
Perform the following steps for all Metropolis
®
DMXtend shelf
Function Unit slots containing 12DS3/EC1 (LNW16) circuit packs and
cabled to a DSX-3 via DS3/EC1 cabling, or the A/B slot containing
LNW39 (DS1/DS3/16/3) and the DS3 portion of the hybrid cable
cabled to a DSX-3.
If the Metropolis
®
DMXtend is cabled to some other type of DS3/EC1
terminating equipment, use this procedure by substituting these ports
for the DSX-3 ports called out in the procedure.
If the Metropolis
®
DMXtend shelf is not fully populated, it may be
necessary to move the circuit pack(s) from slot to slot in order to test all
DS3/EC1 cabling.
This procedure requires the use of a DS3 test set.
Important!
The LNW16 circuit packs are provisioned on a "per
port" basis for DS3 or EC1. Provisioning of the ports for EC1 will
be supported in Release R1.1 and later. The default setting for all
ports is DS3. Tests in the section will verify proper cabling by using
a DS3 test set with all ports provisioned as DS3.
The LNW39 (DS1/DS3/16/3) pack’s DS3 portion is only
provisionable for DS3.
Verify Provisioning
Step 1
For the LNW16, verify that all ports are provisioned for DS3.
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-t3
command.
............................................................................................................................................................................
Step 2
Click on the
rtrv-t3
command.
............................................................................................................................................................................
Step 3
Under the
Parameters
section, click on
{a}-{all}
under the
<T3AIDRTRV>
column.
Double click on {a} and choose the Function Group where the LNW16
is located.
Result:
One of the following commands will be displayed in the
Command Builder
window to the left of the
Send
button.
rtrv-t3:lt-dmxtend:d-all:ctag; (for Function Group d)
rtrv-t3:lt-dmxtend:g-all:ctag; (for Function Group G).