Operational Tests
Manual Switching Tests
...........................................................................................................................................................................................................................................................
5 - 1 5
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
Manual Switching Tests
Description
This test will initiate switching commands from the CIT TL1
Command Builder and verify proper switching and LED indications.
Main OLIU Switch Test
Important!
An STS1 cross-connect should still exist from the
previous tests.
Step 1
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-state-path
command.
............................................................................................................................................................................
Step 2
Click on the
rtrv-state-path
command.
............................................................................................................................................................................
Step 3
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication as well as indicating whether
Ring 1 or Ring 2 is the active ring.
The M1 OLIU is associated with Ring 1 and the M2 OLIU is associated
with Ring 2.
............................................................................................................................................................................
Step 4
Use the scroll bar in the
Command Builder
window to scroll down to
the
opr-protnsw-sts1
command.
............................................................................................................................................................................
Step 5
Click on the
opr-protnsw-sts1
command.
............................................................................................................................................................................
Step 6
If the active ring is Ring 2, change the
m{1}-1-{1}
parameter listed
under the
<STS1PROTN>
column to
m{2}-1-{1}
by double clicking on
1
between the brackets
{ }
and selecting
2
from the drop down window.
............................................................................................................................................................................
Step 7
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication.