Operational Tests
Manual Switching Tests
5 - 1 8
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................
Step 7
Under the
Parameters
section, choose the corresponding Function
Unit or Growth Slot from the choices given under the
<SWPAIRAID>
parameter.
............................................................................................................................................................................
Step 8
Under the
Parameters
section,
<MODE>,
choose
NORM
.
............................................................................................................................................................................
Step 9
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication.
............................................................................................................................................................................
Step 10
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-state-eqpt
command.
............................................................................................................................................................................
Step 11
Click on the
rtrv-state-eqpt
command.
............................................................................................................................................................................
Step 12
Click
Send
to issue the command.
Result:
The
Response Window
should display the command
followed by a
COMPLD
indication as well as indicating which
Function Unit and/or Growth Slot circuit pack is active and which is
standby.
This information should agree with the
ACTIVE
LEDS on the
LNW6/LNW7 (28DS1), LNW16 (12DS3/EC1) or LNW39 (DS1/
DS3/16/3) circuit packs.
Important!
Equipment protection switching is not supported on
the LNW36(R1.1) and LNW46(R1.1) OLIUs.
............................................................................................................................................................................
Step 13
Repeat Step 1 through Step 9 to verify a switch back to the original
Function Unit or Growth Slot circuit pack.
............................................................................................................................................................................
Step 14
Repeat this procedure for each Function Unit and/or Growth Slot pair.