Ring Setup and Testing: Integration Procedures
OC-3 Optical Transmission Test
...........................................................................................................................................................................................................................................................
6 - 9
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
OC-3 Optical Transmission Test
Procedure
Step 1
Use the scroll bar in the
Command Builder
window to scroll down to
the
init-reg-all
command.
............................................................................................................................................................................
Step 2
Click on the
init-reg-all
command. Select all from the <Default AID>
and double click on the 15-min within the <TMPERINIT> and select
all.
............................................................................................................................................................................
Step 3
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication.
............................................................................................................................................................................
Step 4
Wait 15 minutes.
............................................................................................................................................................................
Step 5
At the test location, enter the following command; replacing TID with
that shelf’s TID:
rtrv-pm-oc3:TID:main-1-1:ctag::,0-UP,NEND,,15-MIN,ALL,;
Requirement:
The Response Window indicates no transmission
errors.
............................................................................................................................................................................
Step 6
Repeat Step 1 thru Step 5 for all Metropolis
®
DMXtend shelves at the
test location.
............................................................................................................................................................................
Step 7
Repeat Step 1 thru Step 5 for each node in the ring.
............................................................................................................................................................................
Step 8
Check off the appropriate box in Appendix E, Installation Checklist.