Metropolis
®
DMXtend Access Multiplexer Horizontal Bay Mount Physical Installation and
Powering
Tools, Test Equipment and
Accessories
...........................................................................................................................................................................................................................................................
P a r t I - 3
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
1
ESD Wrist Strap
R-4987C
A wrist strap must be worn when handling
circuit packs. Use the electrostatic discharge
(ESD) jack provided on the shelf.
1
Torque Wrench
R-5952
A torque wrench (50-250 IN-LBS) is used
when tightening the Metropolis
®
DMXtend
shelf to the frame. It is also used when
reattaching the mounting brackets to the
Metropolis
®
DMXtend
shelf.
1
Metric & Inch Series Tool
Set
R - 6001
Because some of our Optical Networking
Products (also know as Transport) may have
some metric fasteners, please ensure that the
proper metric tools are available.
1
Multimeter (Optional)
ITE-6379C
The voltmeter must be capable of measuring
DC voltage in the 40 to 60 volt range. The use
of the voltmeter is optional since the shelf will
alarm or shut down if the proper voltage is not
supplied.
1
Ohmmeter
ITE-6379C
An ohmmeter is required to verify that the
Metropolis
®
DMXtend is properly grounded.
1
DS1 Error Rate Test Set
ITE-7113
A DS1 error rate test set is required for testing
of DS1 cabling. A T-BERD 2209 or equivalent
is recommended.
1
DS3 Error Rate Test Set
ITE-7113
A DS3 error rate test set is required for testing
of DS3 cabling. A T-BERD 209 or equivalent is
recommended.
1
Optical Test Set (Optional)
A Optical test set is required for testing of low
speed optics OC3/12/48. An Omniber 718 or
equivalent is recommended.
2 or 3
LC-type Optical Fiber
Jumper ITE-7169
(108918269)
Two optical fiber jumpers with LC type
connectors are required to optically loop the
Metropolis
®
DMXtend shelf for test purposes.
In addition, for shelves containing optical
circuit packs in any of the Function Unit slots, a
single optical fiber jumper is required for
testing of the individual ports.
Quantity
Description
Comments