Equipment and Cable Installation for Metropolis
®
DMXtend
Shelf Horizontal Bay Mount
Power Cable Installation
...........................................................................................................................................................................................................................................................
1 - 1 5
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
Power Cable Installation
Description
This section provides instructions on installing the power cable and
cable bracket for the Metropolis
®
DMXtend shelf.
Two feeders (A and B) are required from the battery distribution fuse
board (BDFB) or battery distribution circuit breaker bay (BDCBB) to
the Metropolis
®
DMXtend bay.
Table 1-2, Power Cable Assemblies and Table 1-3, Power Connections
(page 1-17) lists the available power cable assemblies and power
connections, respectively.
CAUTION
Verify that the BDCBB breakers are off or that the BDFB fuses
are not installed.
............................................................................................................................................................................
Procedure
Step 1
Connect the A and B power cables to the A and B power connector
housings on the back of the Metropolis
®
DMXtend Shelf. See
Figure 1-6, Power Connection (page 1-15).
CAUTION
Ensure that the 4 parts of the terminal inside the connector
attached to the power cable are properly aligned before
inserting the connector into the power connector housing.
Failure to so may result in damage to the connector.
Figure 1-6
Power Connection