Equipment and Cable Installation for Metropolis
®
DMXtend
Shelf Horizontal Bay Mount
10/100BASE-T/TX Ethernet Cable Installation
1 - 4 8
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
Figure 1-16 10/100BASE-T/TX Cable Routing
............................................................................................................................................................................
Step 4
Route the cables along the cable rack and into the terminating bay.
............................................................................................................................................................................
Cut cable to length and punch down cable to the 110 block. Refer to
for pin out assignments.
CAUTION
...........................................................................................................................................................................
The LNW66 10/100 BaseT-Ethernet pack does not have
lightning protection for the metallic connections. Therefore it is
necessary to use a lightning protected patch panel, such as the
Black Box CAT5 protected patch panel JSM110A, for intra-
office applications only.
............................................................................................................................................................................
Step 6
Check off the appropriate box in Appendix E, Installation Checklist.
...........................................................................................................................................................................
End of Steps