Software Download and Circuit Pack Installation
Circuit Pack Installation
3 - 4
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
Circuit Pack Installation
Description
This section provides instructions and the recommended order for
installing (fully seating) the circuit packs in the Metropolis
®
DMXtend
shelf. The procedures in this section assume that the SYSCTL is
installed and software has been successfully downloaded as described
in the section, Software Installation (page 3-3).
Locations of circuit packs (Function Unit slots) are shown in
Figure 2-2, Metropolis® DMXtend Shelf (page 2-10).
Circuit packs are keyed to prevent being inserted into the wrong shelf
position. Installing circuit packs requires some force.
CAUTION
When installing the circuit packs, be careful to insert them
straight to avoid damaging the backplane pins.
When a circuit pack is installed, its
FAULT
LED will light for several
seconds then extinguish.
CAUTION
A properly grounded ESD wrist strap MUST be worn when
handling circuit packs.
Important!
The
UPD/INIT
push button on the SYSCTL circuit
pack is recessed and will require a pointed object.
............................................................................................................................................................................