Installation Tests
Overview
4 - 2
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
Tools, Test Equipment and
Accessories
Listed below are the required tools, test equipment and accessories
For complete listing see Part I or Part II.
............................................................................................................................................................................
Quantity
Description
Comments
Screwdriver(s)
A screwdriver(s) with the appropriate head(s) is
(are) required for securing the mounting
screws, repositioning the mounting brackets,
installing the interfacing cables, and for setting
the circuit breakers to the OFF position.
1
ESD Wrist Strap
A wrist strap must be worn when handling
circuit packs. Use the electrostatic discharge
(ESD) jack provided on the shelf.
1
DS1 Error Rate Test Set
A DS1 error rate test set is required for testing
of DS1 cabling. A T-BERD 2209 or equivalent
is recommended.
1
DS3 Error Rate Test Set
A DS3 error rate test set is required for testing
of DS3/EC1 cabling. A T-BERD 2209 or
equivalent is recommended.
2 or 3
LC-type Optical Fiber
Jumper (108918269)
Two optical fiber jumpers with LC-type
connectors are required to optically loop the
Metropolis
®
DMXtend shelf for test purposes.
In addition, for shelves containing optical
circuit packs in any of the Function Unit slots, a
single optical fiber jumper is required for
testing of the individual ports.
1
15 dB LC-type LBO
(108279480)
For shelves containing optical circuit packs in
any of the Function Unit slots (supported
starting in release R1.1), a single 15 dB LBO is
required for testing of the individual ports
1
Personal Computer (PC)
Required to run the WaveStar™ CIT software.
See PC Minimum Requirements (page 3-2).
1
CIT (RS-232) Interface
Cable
8-ft. long RJ45 to 9-pin D-sub serial cable
(Comcode 848748869). Required to connect
the PC to the CIT jack on the front of the
SYSCTL circuit pack.
2
LAN 10BaseT Straight-
through Cable CAT 5 or
better
As required to reach from front of DMX to the
RJ45 patch panel