Installation Tests
Local Equipment and Cross-connect Tests
4 - 2 8
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
Requirement:
The flashing FAULT LED should extinguish on the OC-3 OLIU.
There should be no alarm indications on the Metropolis
®
DMXtend
shelf.
............................................................................................................................................................................
Step 12
Remove the 15dB LBO from the OC-3 OLIU (Port 2) and place it on
the
IN
connector directly below it (Port 3).
Connect the fibers labeled IN and OUT from the LGX to the OLIU
(Port 3).
............................................................................................................................................................................
Step 13
Connect the Port 3
OUT
connector to the Port 3
IN
connector (at the
LGX) of the OC-3 OLIU, using an optical fiber jumper cable.
Requirement:
The FAULT LED on the OC-3 OLIU will begin flashing and the
MN
and
NE
LEDs should be lit on the SYSCTL circuit pack.
After approximately 20 seconds the flashing
FAULT
LED should extinguish
on the OC-3 OLIU and the FAULT,
MJ
and
NE
LEDs should be lit on the
SYSCTL circuit pack.
............................................................................................................................................................................
Step 14
Remove the optical fiber jumper from the OC-3 OLIU (at the LGX).
Result:
The FAULT LED should begin flashing on the OC-3
OLIU and only the MN and NE LEDs should be lit on the SYSCTL
circuit pack.
............................................................................................................................................................................
Step 15
Use the scroll bar in the
Command Builder
window to scroll down to
the
upd-sys
command. Click on the
upd-sys
command.
............................................................................................................................................................................
Step 16
Click
Send
to issue the command.
Result:
The
Response Window
should display the command
followed by a
COMPLD
indication.
Requirement:
The flashing
FAULT
LED should extinguish on the OC-3 OLIU.
There should be no alarm indications on the Metropolis
®
DMXtend
shelf.