Operational Tests
Final Operations
...........................................................................................................................................................................................................................................................
5 - 3 1
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
Final Operations
Description
The following procedure ensures that all test signals and cross-connects
have been removed and the Metropolis
®
DMXtend shelf is alarm free
and ready for network connection procedures.
Procedure
Step 1
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-crs-sts1
command.
............................................................................................................................................................................
Step 2
Click on the
rtrv-crs-sts1
command.
............................................................................................................................................................................
Step 3
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication as well as indicating the cross-
connect entered earlier.
............................................................................................................................................................................
Step 4
Use the scroll bar in the
Command Builder
window to scroll down to
the
dlt-crs-sts1
command.
............................................................................................................................................................................
Step 5
Click on the
dlt-crs-sts1
command.
............................................................................................................................................................................
Step 6
Under the
Parameters
section,
<STS1CRSSRC>,
click on
m-1-{1}
.
............................................................................................................................................................................
Step 7
Under the
Parameters
section,
<STS1CRSDST>,
click on
{a}
-{1}
from.
............................................................................................................................................................................
Step 8
Double click the
a
and choose the letter corresponding to the cross-
connect displayed in Step 3.