Ring Setup and Testing: Integration Procedures
Manual Switching Tests
...........................................................................................................................................................................................................................................................
6 - 1 3
Lucent Technologies - Proprietary
See notice on first page
365-372-327 R2.0
Issue 1, October 2003
............................................................................................................................................................................................................................................................
Manual Switching Tests
Description
This test will initiate switching commands from the CIT and verify
proper switching and LED indications.This test may be performed on
the following circuit packs:
LNW38, LNW40, or LNW51
Main OLIU Switch Test
Important!
An STS1 cross-connect is required in order to perform
manual switching.
Step 1
Enter an STS1 cross-connect between an equipped Function Unit and
the Main OLIU.
............................................................................................................................................................................
Step 2
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-state-path
command. There must be a cross connect present in
order for this command to retrieve any information.
............................................................................................................................................................................
Step 3
Click on the
rtrv-state-path
command.
............................................................................................................................................................................
Step 4
Click
Send
to issue the command.
Result:
The Response Window should display the command
followed by a
COMPLD
indication as well as indicating whether
Ring 1 or Ring 2 is the active ring.
The M1 OLIU is associated with Ring 1 and the M2 OLIU is associated
with Ring 2.
............................................................................................................................................................................
Step 5
Use the scroll bar in the
Command Builder
window to scroll down to
the
opr-protnsw-sts1
command.
............................................................................................................................................................................
Step 6
Click on the
opr-protnsw-sts1
command.
............................................................................................................................................................................
Step 7
If the active ring is Ring 2, change the
m{1}-1-{1}
parameter listed
under the
<STS1PROTN>
column to
m{2}-1-{1}
by double clicking on
1
between the brackets
{ }
and selecting
2
from the drop down window.