Observing Boot Messages
A-4
INA Module Installation and Configuration Guide
Use Table A-2 to interpret possible diagnostic boot messages.
Table A-2
Interpreting Diagnostic Boot Messages
Field
Possible Message
Explanation
INA PROM
N
Version number of the
installed boot PROM.
Testing System Clock
ERROR
This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.
Sizing System Memory
ERROR at failed
memory address.
This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.
CPU Type
486DX5-133
The type of CPU installed.
Starting FLASH Boot
N/A
N/A
Flash Memory
Am29F016 4096K
Nonvolatile RAM brand
name and size in kilobytes.
16384
16384
Counter for system
memory dynamic RAM
(DRAM) size. If the size
counter freezes, record all
information to this point
and contact Lucent
technical support.
Verifying Load Module Checksum
Invalid Length for
Flash at RAM
address.
This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.
Starting Loader
N/A
N/A
Testing High Memory
ERROR at failed
memory address
This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.
Summary of Contents for Network Access Module
Page 4: ......
Page 32: ......
Page 40: ...Configure the WAN Port 5 8 INA Module Installation and Configuration Guide ...
Page 56: ...Using the DS 1 Test Jacks A 8 INA Module Installation and Configuration Guide ...
Page 60: ...Crossover Cable B 4 INA Module Installation and Configuration Guide ...
Page 70: ...INA Module System Interactions C 10 INA Module Installation and Configuration Guide ...