255-700-025
4-21
PacketStar
™
Access Concentrator 60 User Guide
, Issue 1
Release 6.3.0
Chapter 4 Configuring the Basic System
Configuring In-Band Management
Begin
Entering the SNMP Trap Destinations
1
Select the
NMS 1
field, and type the IP address value of the remote
management station to which you want to send SNMP traps.
2
Under the
Source Addr
field, select one of the following values (see
Table 4-5):
3
Press
Enter
to exit edit mode.
4
Repeat steps 1-3 for each network management station to be defined
(up to a total of five).
5
Select the
Apply Site-Specific Configuration
command and press
Enter.
System Response: After you apply (save) the values on this window, the
system does the following:
~
Writes the values you entered to the AC 60 system database
~
Displays your site name in the upper right corner of the window
~
Displays the local time in the
[Local Time]
field.
6
To return to the Console Interface Main Menu window, press
C tr l+ B
.
End
Configuring In-Band Management
If you want to manage one or more Access Concentrator systems over an
ATM wide-area network (WAN), you can set up an Access Concentrator or a
network management system (NMS) computer to provision either PVC or
SVC connections to the remote Access Concentrator systems to be managed.
For a PVC connection, you set up the management host, which is usually a
Unix workstation running an SNMP client that manages one or more Access
Table 4-5. Field Values for the SNMP Trap Destinations Panel
Field Value
Description
Interface (default)
Sets the source address used in all SNMP
traps to the IP address of the interface from
which they are sent
Ethernet
Sets the source address used in all SNMP
traps to the Ethernet IP address from which
they are sent
Ibm
Sets the source address used in all SNMP
traps to the inband IP address from which
they are sent