255-700-025
C-13
PacketStar
™
Access Concentrator 60 User Guide
, Issue 1
Release 6.3.0
Appendix C Configuring In-Band Management
Using the Hybrid Connection Configuration
Primary IP Mask: 255.000.000.000
2
Configure the primary and backup IP Address for in-band management
on the CPU module of the intermediate router PSAX system (Node B)
using the console interface:
Example:
Primary IP Address: 020.001.001.2
Primary IP Mask: 255.000.000.000
3
Configure the primary IP address for in-band management on the CPU
module of the main router PSAX system (Node C) using the console
interface:
Use
[Site Specific Configuration]->[ In-Band Management]
menu.
Example:
Primary IP Address: 020.001.001.003
Primary IP Mask: 255.000.000.000
4
Configure the primary IP Address for in-band management on the CPU
module of main router PSAX system (Node D) using the console
interface:
Use
[Site Specific Configuration]->[ In-Band Management]
menu.
Example:
Primary IP Address: 020.001.001.004
Primary IP Mask: 255.000.000.000
5
Configure the primary IP address for in-band management on the CPU
module of main router PSAX system (Node E) using the console
interface:
Use
[Site Specific Configuration]->[ In-Band Management]
menu.
Example:
Primary IP Address: 020.001.001.005
Primary IP Mask: 255.000.000.000
6
Set up in-band management connections on the CPU module of Node A
to a remote PSAX system:
For setting up an in-band connection from the DS3 card to the CPU
module, configure the DS3 card and put it into service. Then using the
console interface
[Connection Configuration]-> [In-Band
Management IP PVC] -> [Add Connection]
screen, configure the PVC
to the FORECARD.
Example:
Slot<Slot>VPI: VPIabIP Address: 020.001.001.002