Chapter 2 Hardware Description
AC 60 System Environmental Specifications
2-6
255-700-025
PacketStar
™
Access Concentrator 60 User Guide
, Issue 1
Release 6.3.0
Table 2-3 provides the environmental specifications for the AC 60 power
supply.
AC 60 CPU and Stratum Component Specifications
This section details the specifications for the installed CPU and Stratum
components for the AC 60 system.
The hardware specifications for the AC 60 CPU component are given in
Table 2-4.
Maximum current:
22.4 A
Maximum power:
540 W
Power input
3 position terminal block on front of unit
Connector Type
3 pin connector (110 and 220)
3- terminal block (-48 V)
Table 2-3. Environmental Specifications for the AC 60 Power Supply
Specification
Range of Values
Operating temperature:
32° to 122° F
0° to 50° C
Storage temperature:
-40° to +158° F
-40° to +70° C
Operating relative humidity:
40 to 60%, optimum;
Up to 95%, noncondensing
Table 1. AC 60 Power Source Requirements
Specification
Description
Table 2-4. AC 60 CPU Component Specifications
Specification
Description
Units per system:
1 factory installed component
Power consumption
18 W, average
Processing:
RISC microprocessor
Memory:
128 MB flash drive
64 MB RAM
Connectors:
One RJ-45 connector labeled ETHERNET and
one RJ-12 connector labeled CONSOLE on the
faceplate
LED indicators:
Two indicators:
• ACTIVE—green
• FAIL—red