255-700-166
7-13
PacketStar
®
PSAX 6-Port DS1 IMA Module User Guide
, Issue 1
Release 7.0
Chapter 7 Provisioning Connections Using the Console Interface
Provisioning PVC Connections
Field Descriptions
Table 7-2. Field Descriptions for the ATM-to-ATM VCC and ATM-to-ATM VPC Connection Statistics
Window
Field Name
Description
AIS Rx/Tx
(display only)
Number of alarm indication signal (AIS) cells received and trans-
mitted..
RDI Rx/Tx
(display only)
Number of remote defect indicator (RDI) cells received and trans-
mitted.
cell Drop/Tag
(display only)
Number of cells dropped and tagged on incoming side of interface
A or B.
Cells Received
(display only)
Number of valid cells received since the virtual circuit or virtual
path was established.
Cells Transmitted
(display only)
Number of valid cells transmitted since the virtual circuit or virtual
path was established.
FEC Rate Used
(ATM-to-ATM
VCC only)
Displays the forward error correction (FEC) rate being used by the
FEC module in the A2B direction (for
ATM Interface A
panel), or
B2A direction (for
ATM Interface B
panel). This field is dymanic
when auto rates are selected. In other cases it will display the rate
set by the user.
Received Odome-
ter
(display only)
Number of valid cells received since this counter was reset.
Note:
This counter serves as an odometer while the
Cells
Received
field tracks usage for the life of the circuit.
Transmitted
Odometer
(display only)
Number of valid cells transmitted since this counter was reset.
Note:
This counter serves as an odometer while the
Cells
Transmitted
field tracks usage for the life of the circuit.
Time Elapsed
(display only)
(displayed on
Interface Side A
Statistics
panel)
Time elapsed since last reset.
Time Since Reset
(display only)
(displayed on
Interface Side A
Statistics
panel)
Time elapsed since the last time the
Reset Statistics
command was
used.
Note:
The
Reset
command on the statistics window resets only
the odometer fields and the corresponding clock.Other counters
increment for the life of the circuit.