Chapter 8 Provisioning Connections Using the AQueView
®
System
Provisioning PVC Connections
8-32
255-700-166
PacketStar
®
PSAX 6-Port DS1 IMA Module User Guide
, Issue 1
Release 7.0
Field Descriptions
The fields on this window are described in Table 8-4.
Table 8-4. Field Descriptions for the ATM-to-ATM VCC and ATM-to-ATM VPC Connection Statistics Page
Field Name
Description
AIS Received
(display only)
Number of alarm indication signal (AIS) cells received.
AIS Transmitted
(display only)
Number of AIS cells transmitted.
RDI Received
(display only)
Number of remote defect indicator (RDI) cells received.
RDI Transmitted
(display only)
Number of remote defect indicator (RDI) cells transmitted.
Cell Drop
(display only)
Number of cells dropped on incoming side of interface A or B.
Cell Tag
(display only)
Number of cell tagged on incoming side of interface A or B.
Cells Received
(display only)
Number of valid cells received since the virtual circuit or virtual
path was established.
Cells Transmitted
(display only)
Number of valid cells transmitted since the virtual circuit or virtual
path was established.
FEC Rate Used
(ATM-to-ATM VCC
only)
Displays the forward error correction (FEC) rate being used by the
FEC module in the A2B direction (for
ATM Interface A
panel), or
B2A direction (for
ATM Interface B
panel). This field is dymanic
when auto rates are selected. In other cases it will display the rate
set by the user.
Received Odometer
(display only)
Number of valid cells received since this counter was reset.
Note:
This counter serves as an odometer while the
Cells
Received
field tracks usage for the life of the circuit.
Transmitted Odometer
(display only)
Number of valid cells transmitted since this counter was reset.
Note:
This counter serves as an odometer while the
Cells
Transmitted
field tracks usage for the life of the circuit.
Time Elapsed
(display only)
(displayed on
Interface
Side A Statistics
panel)
Time elapsed since last reset.
Time Since Reset
(display only)
(displayed on
Interface
Side B Statistics
panel)
Time elapsed since the last time the
Clear
button was used.
Note:
The
Clear
button resets only the odometer fields (labelled
as
Odometer
) and the corresponding clock. Other counters
increment for the life of the circuit.