255-700-166
8-113
PacketStar
®
PSAX 6-Port DS1 IMA Module User Guide
, Issue 1
Release 7.0
Chapter 8 Provisioning Connections Using the AQueView
®
System
Provisioning PVC Connections
If the parameters are valid, the Connections window appears with the
new connection in the
Listing
page, and the Display Connection
window appears with tabs that contain details about the connection (see
Figure 8-60):
Primary, Statistics,
Backup
, and
Utilization
.
If a parameter is invalid, a
Connection Creation Failed
message appears,
stating the reason for the failure.
Primary Page
The
Primary
page displays the information used to create the connection. See
Table 8-20 for field descriptions.
OAM Status
Default: Unsupp
OAM is not in use.
End-Pt
The PSAX system is used as a termination point for ATM
traffic, and will process AIS/RDI cells.
Note:
The OAM loopback test is supported for end-to-
end connections only.
End-Seg-Pt
Has the characteristics of both an end point and a segment
point.
Connection Sta-
tus
(display only)
Default: Inactive,
Active
This field displays the current status of the connection.
The value indicates whether the connection is passing
traffic.
Connection Fail-
ure Cause A
(display only)
None (default)
Physical
General connection failure cause.
Connection Fail-
ure Cause B
(display only)
None (default)
Physical
General connection failure cause.
Table 8-20. Field Values for the VBR-to-ATM _VCC Connection Window
Field Names
Values
Description